Fitting/removing a power module
The RED-PSUPRO main chassis can accommodate two power modules, although
operation is perfectly possible with just one module tted. The addition of a second
module provides redundancy for critical installations.
IMPORTANT: To ensure correct and reliable operation, only Adder power
modules may be used with the RED-PSUPRO.
Note: Module bay 1 is on the left as you view the rear of the RED-PSUPRO chassis,
module bay 2 is on the right.
To t a power module
Note: Power modules are hot-pluggable (i.e. while
power is applied to the other module), be sure
to observe safe working practices and anti-static
precautions when tting a module to a working
RED-PSUPRO chassis.
1 If a blanking plate is tted, remove it to
reveal the power module bay.
2 Observing suitable anti-static precautions,
remove the new power module from its
packing.
3 Carefully slide the power module into the
vacant bay until the locking clip ‘clicks’ to
hold the module in place.
To remove a power module
Note: Power modules are hot-pluggable (i.e. while power
is applied to the other module), be sure to observe safe
working practices and anti-static precautions when
removing a module from a working RED-PSUPRO chassis.
1 Isolate power from the module to be removed and
disconnect the IEC power cord.
2 Push the locking lever to the left so that the
module un-clips and use the handle to carefully pull
the module out of the bay.
3 If no replacement module is to be used, t a
blanking plate to cover the vacant bay.
4 Insert an IEC power cord into the socket
on the module and apply power to the
module.
IMPORTANT: Please read and adhere to the electrical safety information
given within the Safety information leaet. In particular, do not use an
unearthed power socket or extension cable.
Note: Various items within the RED-PSUPRO casing generate heat when in operation and will
become warm to the touch. Ensure that air can circulate freely at the rear of the enclose,
particularly by the power module cooling fans. Do not operate the equipment in ambient
temperatures exceeding 50 degrees Centigrade. Do not place the products in contact with
equipment whose surface temperature exceeds 50 degrees Centigrade.