Installation
LOCATION
Please consider the following important points when planning the position of the RED-
PSUPRO unit:
• The RED-PSUPRO main chassis occupies a single 1U (19”) rack slot and requires
either one or two (when the redundancy option is used) mains inputs.
• For devices that require a 12VDC supply, a 2m link cable (VSC48) is required.
• For devices that require a 5VDC supply, small Converter dongles (PSU-RPS-5V-3M) are
required to be positioned close to the devices being powered. The converter dongle
can be up to 3m away from the RED-PSUPRO main chassis. See opposite for details.
• Consult the precautions listed within the Safety information section.
Mounting converter dongles
For each device that requires a 5VDC supply (12VDC devices require only a simple
cable), a Converter dongle is required. Each converter dongle must be placed in close
proximity to the device. To assist with mounting dongles in congested spaces, an optional
elongated rack bracket is available for AdderLink Innity units (see page 3) that allows
each dongle to be positioned just behind the device that it is powering.
Insert the tabs of the dongle
through the wider spaced holes of
the rack bracket and then slide the
dongle back to lock it in place.
Note: The indentations on the side
of the converter dongle allow it to
be xed to other surfaces using a
single plastic cable tie.