For example Tracer10420AN 48V system:
4.2 Troubleshooting
Faults
Possible reasons
Troubleshooting
The LED&LCD is off
during daytime when
sunshine falls on PV
modules properly
PV array disconnection
Confirm that PV and battery wire
connections are correct and tight
Wire connection is
correct, LCD not display
Battery voltage is lower
than 8V
Please check the voltage of
battery. At least 8V voltage to
activate the controller
Fault LED indicator
flashing
Interface
blink
Battery voltage higher
than over voltage
disconnect voltage(OVD)
Check if the battery voltage is too
high, and disconnect the solar
module
Fault LED indicator
flashing
Interface
blink
Battery under voltage
Load output is normal, charging
LED indicator will return to green
automatically when fully charged
Charging and fault LED
indicator flashing
Interface
blink
Battery over temperature
The controller will automatically
turn the system off. When the
temperature declines to be below
55 ºC, the controller will resume.
0
1000
2000
3000
4000
5000
6000
75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91
Charge power W
Internal temperatureȻ
Reduce charging power mode
Power W