ACOPower HY-SPKP-600W50A handleiding

36 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 26 van 36
www.acopower.com
20
4 Protections, Troubleshooting & Maintenance
4.1 Protections
WARNING: Do not reverse the polarity of the batteries. Reverse polarity will damage the charge controller permanently. Damage caused
by reverse polarity, is not covered by warranty.
PV Over
Current/power
When the charging current or power of the PV array exceeds the controllers rated current or power, it will be charge at the rated current
or power.
NOTE: When the PV modules are in series, ensure that the open-circuit voltage of the PV array does not exceed the "maximum
PV open-circuit voltage" rating. Otherwise the controller may be damaged.
PV Short Circuit
When not in PV charging state, the controller will not be damaged in case of a short-circuiting in the PV array.
PV Reverse
Polarity
When the polarity of the PV array is reversed, the controller may not be damaged and can continue to operate normally after the
polarity is corrected.
NOTE: If the PV array is reverse connected to the controller,1.5 times rated controller power(watts)from the PV array, will
damage the controller.
Night Reverse
Charging
Prevents the battery from discharging through the PV module at night.
Battery Over
Voltage
When the battery voltage reaches the over voltage disconnect voltage, it will automatically stop battery charging to prevent battery
damage caused by over-charging.
Battery Over
Discharge
When the battery voltage reaches the low voltage disconnect voltage, it will automatically stop battery discharging to prevent battery
damage caused by over-discharging. (Any controller connected loads will be disconnected. Loads directly connected to the battery will
not be affected and may continue to discharge the battery.)
Battery
Overheating
The controller can detect the battery temperature through an external temperature sensor.The controller stops working when its
temperature exceeds 65 °C and restart to work when its temperature is below 55 °C.
Controller
Overheating
The controller is able to detect the temperature inside the battery. The controller stops working when its temperature exceeds 85 °C
and restart to work when its temperature is below 75 °C.
TVS High Voltage
Transients
The internal circuitry of the controller is designed with Transient Voltage Suppressors (TVS) which can only protect against high-voltage
surge pulses with less energy. If the controller is to be used in an area with frequent lightning strikes, it is recommended to install an
external surge arrester.
When the internal temperature is 81, the reducing power charging mode which reduce the charging power of 5%,10%,20%,40% every
increase 1 is turned on. If the internal temperature is greater than 85, the controller will stop charging. But while the temperature
decline to be below 75 ºC, the controller will resume.