Table of Parameters and Factory Settings
Parameter Function Set Range Default Parameter Function Set Range Default
Set
Setpoint
20°C
C3H
Product Temp. High
Temp. Alarm
C3L~80.0°C/176°F
70°C/158°F
PAS
Password 00~99 15
C3L
Product Temp.
Low Temp. Alarm
-40°C/--40°F~C3L
0.0°C/32.0°F
E1 Lowest set Set temp. ~ -4°C /39.2°F
4°C /
39.2°F
C4
Hysteresis
0.1~20.0°C / 0.1°C /
point limit
Alarm
0.2~36.0°F
32.18°F
E2
Higher set point
limit
60.0°C / 140.0°F ~set
temp.
60.0°C /
140°F
C5
Start-up Temp.
Alarm delay
00~99 min 60 min
E30
Temp.
Hysteresis
1.5°C /
34.7°F
1.5°C /
34.7°F
E31
Heating
Temp.
Hysteresis
0.1~20.0°C /
32.18~68.0°F
1.5°C /
34.7°F
C6
Temp. Alarm
Delay
00~99 min 15 min
E40
Turning On delay
time
00 ~10 min. 3 min.
C7
Power Off relay
Alarm
00=do not alarm / 01=
alarm
01
E41
Comp. start delay
time
00 ~10 min. 3 min.
C8
Alarm relay
close after,
muffle alarm
relay switch
00=open /
01=close
00
E5
Offset on Air
Temperature
-10.0~10.0°C / -
14.0~50.0°F
2.0°C /
35.6°F
C9
Restart time
after buzzer
mute
00=do not start /
01 ~30 min=restart
time
10 min
E6
Offset on
Product Temp.
-10.0~10.0°C /
14.0~50.0°F
0.0°C/
32°F
C10
Comp. Force
stop time
01~99 min 99 min
F0
Defrost Type
00=defrost by turning of
comp.
00
C11
Comp. Force
Running Time
00=comp. Stop /
01-99min=starting
time
0 min
F1
Max defrost
duration
01~60 min.
20 min.
C12
Alarm Output
Type
00=contact actuation
when alarm /
01=contact disconnect
when alarm
01
F2
Defrost Interval
(XXhr/time)
00~24 hr. 00
C13
Normal State
temp. display
type
00=liquid bottle temp /
01=cabinet air temp.
00
F4
Temp. displaying
on screen when
defrost
00= normal Temp;
01=latest Temp. 02=Fixed
Temp. ; 03=showing “dEF”
on screen
00
CF
Temperature Unit
°C=Celsius /
°F=Fahrenheit
°C
C0
Hot and cold
conversion
delay time
00-30min 02min
do1
Door open alarm
00=do not alarm
/01=99min=delayed
alarm
02 min
C1
High Temp Air
Alarm
C2~80.0°C / 176.0°F
70.0°C /
158°F
do2
Comp. status
when door open
0=stop /
01=original status
0 1
C2
Low Temp Air Alarm
-40°C / -40°F~C1
0.0°C /
32.0°F
do3
Heating control
mode selection
00=Controlled by
parameters
01 = PID intelligent
control
00