Accucold ABOD15 handleiding

42 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 13 van 42
13
The following are examples of how to change common settings:
A. Enter Password - Press and hold the SET button 6 seconds until it flashes [PAS] then enter the default
password 15 using the UP and DOWN arrows. When 15 is reached press the SET button.
B. Change display to °F in lieu of °C - After entering the password press the SET button about 25 times to
reach the [CF] display, then press the up or down arrow unit the control displays [°F] then press SET.
Wait 6 seconds and it will be set and the unit will go back to normal operation.
C. High Air Alarm Settings - After entering the password press the SET button until you reach the [C1]
display, then press the UP or DOWN arrow unit the control displays your desired setting then press SET.
Wait 6 seconds and it will be set and the unit will go back to normal operation.
D. Low Air Alarm Settings - After entering the password press the SET button until you reach the [C2]
display, then press the UP or DOWN arrow unit the control displays your desired setting then press SET.
Wait 6 seconds and it will be set and the unit will go back to normal operation.
E. High Product Alarm Settings - After entering the password press the SET button until you reach the
[C3H] display, then press the UP or DOWN arrow unit the control displays your desired setting then
press SET. Wait 6 seconds and it will be set and the unit will go back to normal operation.
F. Low Product Alarm Settings - After entering the password press the SET button until you reach the [C3L]
display, then press the UP or DOWN arrow unit the control displays your desired setting then press SET.
Wait 6 seconds and it will be set and the unit will go back to normal operation.
G. Other Parameters in the “Factory Settings”: Enter the Password and then press the SET button until the
desired parameter is displayed, then press the UP or DOWN arrow until the desired setting is displayed
then press the SET key again. Wait 6 seconds and it will be set and the unit will go back to normal
operation.
Recording The Highest and Lowest Temperature
Once turned on and after the [C5] delay, the unit will start to record the highest and lowest temperature; the
record will be refreshed at any time. The values will be kept in memory even after the power is turned off.
Press the HI/LO button to see the highest temperature recorded. Press it again to see the lowest temperature.
Holding the HI/LO button for 6 seconds will cause the display to flash and a buzzer to sound; the previous
highest and lowest temperature readings will be cleared, and a new record will begin. (Highest and lowest
temperature recording instructions: When parameter F4=0, the unit can record highest and lowest
temperature at any time. When F4=1,2,3, during defrost and delay locking 20 minutes, highest and lowest
temperatures are not recorded.
During air sensor failure, highest and lowest temperatures are not recorded. When set C13=00, the
temperature in the liquid bottle is recorded; when set C13=01, the temperature of the air in the cabinet is
recorded. The product temperature corresponds to the temperature of the liquid in the bottle.
Factory Default Resumption
Press and hold the DOWN arrow; at the same time, press the UP arrow and hold for 6 seconds. The display will
flash and show [888]. At this time, all parameters will resume factory default values. After 6 seconds, normal
operational mode will return.
To Check or Change the Password:
Enter the inner parameter menu (PAS display) and enter the correct password. After entering the inner
parameter PAS, press the UP or DOWN arrow to display and change the password, then press HI/LO to confirm
and store the new password.