Zoppas PBA17420SK handleiding

40 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 17 van 40
Problem Possible cause Solution
The room temperature is too high. Decrease the room temperature.
Water flows on the rear plate
of the refrigerator.
During the automatic defrosting proc-
ess, frost defrosts on the rear plate.
This is correct.
Water flows into the refrigera-
tor.
The water outlet is clogged. Clean the water outlet.
Products prevent that water flows in-
to the water collector.
Make sure that products do not touch
the rear plate.
Water flows on the ground. The melting water outlet does not
flow in the evaporative tray above
the compressor.
Attach the melting water outlet to the
evaporative tray.
The temperature in the appli-
ance is too low.
The temperature regulator is not set
correctly.
Set a higher temperature.
The temperature in the appli-
ance is too high.
The temperature regulator is not set
correctly.
Set a lower temperature.
Replacing the lamp
Caution! Disconnect the plug from the mains
socket.
Remove the screw from
the lamp cover.
Remove the lamp cover
(refer to the illustration).
Replace the used lamp
with a new lamp of the
same power and specifi-
cally designed for house-
hold appliances (the
maximum power is
shown on the lamp cov-
er).
Install the lamp cover.
Tighten the screw to the
lamp cover.
Connect the plug to the
mains socket.
Open the door. Make
sure that the light comes
on.
Closing the door
1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installa-
tion".
3. If necessary, replace the defective door gaskets.
Contact the Service Center.