❺ Troubleshoong
Before you contact the retailer, carry out these few simple checks using the following tables
if a problem occurs.
If the problem is not resolved, contact your retailer.
5.1 I Appliance behaviour
Malfuncon Possible causes Soluons
The display does not
work.
The appliance is no longer
supplied with electricity.
Check that the terminal block behind the
regulator is connected properly.
The indicator(s)
and/or is (are)
steadily lit, but the
appliance is not
heang.
Non-compliant appliance
installaon.
Contact a qualied technician.
The pool water is
hoer than requested.
The regulator is not
operang correctly.
Check that the power contactor is not
damaged.
Check that the temperature sensor is
properly inside its thermowell.
The
indicator is
lit on the appliance
alongside the message
"iA" (no audible
signal).
No ow.
Fail-safe thermostat has
been tripped
Check the ow switch and wiring
Check the fail-safe thermostat and wiring
Reset the thermostat:
- Remove the cap on the side of the
appliance,
- Press the centre buon
The
indicator is
lit on the appliance
alongside the message
"Pr" (+ audible
signal*).
The regulaon sensor is out
of service or disconnected.
Check the regulator sensor and wiring
Contact a qualied technician to replace the
regulaon
If the problem connues, contact your retailer.