Warming Potenal (GWP) of 675 for R32 and 2088 for R410A (European regulaon
EU 517/2014).
In order to comply with the applicable standards and regulaons in terms of the
environment and installaon, in parcular Decree No. 2015-1790 and/or European
regulaon EU 517/2014, a leak test must be performed on the cooling circuit when
the appliance is rst started and at least once a year. This operaon must be carried
out by a specialist cered to test cooling appliances.
The appliance must be stored in a well-venlated locaon away from all ignion
sources.
Install the unit outdoors. Do not install the unit indoors or in an enclosed and non-
venlated outdoor locaon.
Do not use means for accelerang the defrosng or cleaning process other than
those recommended by the manufacturer.
The appliance must be stored in a room without any permanent ignion source
(such as open ames, operang gas appliance or operang electric heang).
No not perforate or incinerate.
Please note that R32 refrigerant may give o a certain odour.
INSTALLATION AND MAINTENANCE
The appliance may not be installed close to combusble materials, or the air duct
inlet of an adjacent building.
With some appliances, it is essenal to t a "protecon grid"-type accessory if the
unit is installed in an area with uncontrolled access.
During installaon, troubleshoong and maintenance, pipes may not be used as
steps: the pipe could break under the weight, spilling coolant and possibly causing
serious burns.
When servicing the appliance, the composion and state of the heat transfer uid
must be checked, as well as the absence of any traces of coolant.
During the appliance's annual sealing test in accordance with applicable legislaon,
the high and low pressure switches must be checked to ensure that they are
securely fastened to the cooling circuit and that they cut o the electrical circuit
when tripped.
During maintenance work, ensure there are no traces of corrosion or oil around
the cooling components.
Before beginning work on the cooling circuit, stop the appliance and wait for a few
minutes before ng the temperature and pressure sensors. Some elements such
as the compressor and piping may reach temperatures in excess of 100 °C and high
pressures with the consequent risk of severe burns.
TROUBLESHOOTING
All brazing must be carried out by qualied brazers.
Replacement pipes must always be made of copper in compliance with standard
NF EN 12735-1.
Leak detecon; pressure test:
- never use oxygen or dry air, risk of re or explosion,
- use dry nitrogen or the mixture of nitrogen and refrigerant indicated on the
informaon plate,
- the test pressure for both the high and low pressure circuits must not exceed 42
bar in cases where the appliance is equipped with the oponal pressure gauge.
The high pressure circuit pipes are made of copper and have a diameter equal to or
greater than 1’’5/8. A cercate as indicated in §2.1 in compliance with standard
NF EN 10204 must be requested from the supplier and led in the installaon's
technical le.