5.2 I Technical specicaons
PM40 MD1 MD2 MD3 MD4 MD5 MD7 MD8 TD7 TD8 TD12
Operang
temperatures
air -8 to 35 °C
water 8 to 40 °C
Power output* kW 4.7 7.5 10.5 11.7 14.7 17.5 22.5 18.5 22.1 31
Voltage 220-240V/50 Hz/1PH 380-415V/50 Hz/3PH
Admissible variaon in voltage ± 10 %
Protecon fuse A 10 16 20 25 25 16
Heang: Maximum
current input
A 5.15 7.94 10.7 12.25 13.11 20.3 19.3 7.63 8.24 13.6
Cooling: Maximum
current input
A 4.92 8.77 10.45 11.35 12.25 18.61 19.3 7.87 8.78 13.47
Minimum cable
secon**
mm² 3 x 1.5 3 x 2.5 3 x 4 5 x 2.5 5 x 4
3G1.5 3G2.5 3G4 5G2.5 5G4
Maximum discharge/
sucon pressure
bar
38/11
Head loss bar 0.1 0.1 0.12 0.12 0.14 0.14 0.16 0.14 0.16 0.3
Water ow rate m³/h 2-3 3 4-6 5-8 6-9 7-10 7-11 7-11 9 13-19
Refrigerant type R32 R410A R32
Refrigerant load kg 0.4 0.75 0.9 1.1 1.15 1.1 2.5 1.25 1.45 1.95
CO
2
equivalent
0.27
tonnes
of CO
2
0.50
tonnes
of CO
2
0.60
tonnes
of CO
2
0.74
tonnes
of CO
2
0.77
tonnes
of CO
2
0.74
tonnes
of CO
2
5.22
tonnes
of CO
2
0.84
tonnes
of CO
2
0.98
tonnes
of CO
2
1,32
tonnes
of CO
2
Approximate weight kg 48 65 74 80 96 117 133 110 125 161
Appliance must have a protecon rang (IP) IPX4 or above. Read the label showing the protecon rang IP for your
product.
* Performance levels: air at 28 °C/water at 28 °C/humidity at 80%.
** Values provided for informaon purposes for a maximum length of 20 metres (calculaon base: NFC 15-100), must be checked and adapted to
the installaon condions and standards of the installaon country.
EN
Bekijk gratis de handleiding van Zodiac PM40, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Zodiac |
Model | PM40 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 8785 MB |