4.2 I Error code display
Display Possible causes Soluons
P1
Faulty inlet water temperature sensor
Sensor disconnected or out of order.
Reconnect or replace the sensor.
P2
Faulty outlet water temperature sensor
Sensor disconnected or out of order.
Reconnect or replace the sensor.
P3
Faulty coil temperature sensor
Sensor disconnected or out of order.
Reconnect or replace the sensor.
P5
Faulty ambient temperature sensor
Sensor disconnected or out of order.
Reconnect or replace the sensor.
P7
Winter frost protecon
/ /
E1
High pressure protecon
High-pressure sensor broken.
Replace the high-pressure sensor.
Water circuit obstructed or
insucient ow.
Remove the obstrucon or increase
the water ow rate.
Cooling circuit obstructed.
Send the pump to the retailer for a
detailed inspecon.
E2
Low pressure protecon
Low-pressure sensor broken.
Replace the low-pressure sensor.
Insucient refrigerant level.
Add refrigerant.
Ambient temperature and input
water temperature too low.
Send the pump to the retailer for a
detailed inspecon.
E3
Faulty water owmeter
Flow switch incorrectly posioned.
Re-make the connecons.
Insucient water ow. Increase the water ow rate.
Broken ow switch.
Replace the ow switch.
Faulty lter pump. Repair or replace the lter pump.
E4
Incorrect phase lead connecon (three-
phase model only)
Incorrect phase lead connecon.
Connect the phase leads in the
right order.
E8
Faulty communicaon
Incorrect connecon.
Re-make the connecons.
E12
Outlet water temperature too low
protecon
Obstructed water circuit. Remove the obstrucon.
Insucient water ow. Increase the water ow rate.
Faulty lter pump. Repair or replace the lter pump.
E13
Outlet water temperature overheang
protecon
Obstructed water circuit. Remove the obstrucon.
Insucient water ow. Increase the water ow rate.
Faulty lter pump. Repair or replace the lter pump.
E14
Protecon against an excessive
temperature dierence between the water
inlet and outlet
Obstructed water circuit. Remove the obstrucon.
Insucient water ow. Increase the water ow rate.
Faulty lter pump. Repair or replace the lter pump.
4.3 I Wiring diagrams
• Wiring diagrams are available at the end of the document see "Schémas électriques / Wiring