1.5 I Opon connecons
Connecng "Heang Priority" opons:
Before any work inside the appliance, you must cut the appliance’s electricity supply as there
is a risk of electric shock which may cause material damage, serious injury or even death.
There is a risk of electrical return current, injuries, material damage and death when
working on terminals 1 to 2.
Any connecon error with terminals 1 to 2 may damage the appliance and invalidate its
warranty.
Terminals 1 to 2 are dedicated to the opons and must never be used to directly supply
other equipment.
Use cables with a secon of at least 2x0.75 mm² , RO2V type and with a diameter between
8 and 13 mm.
Before connecng any opons: remove the seal (above the cable gland) and install the cable gland provided in order to
pass the cables into the appliance.
The cables used for the opons and the power cord must be kept separate (risk of interference) using a collar inside the
appliance just aer the glands.
1.5.1 "Heang priority" opon
This funcon allows the appliance to start ltraon (connuously or in 5-minute cycles every 120
minutes) in order to detect the water temperature and thus acvate the ltraon + heang unit to
maintain a constant water temperature. The lter pump is thus said to be slaved to the heang system.
Filtraon is kept in operaon or acvated if the pool temperature falls below the desired temperature.
When making the connecons, make sure that the appliance is powered o, connect a 230 VAC NO relay (not included)
to terminals 1 and 2 (230 V output), then connect the connecon cable (not included) from the output of this relay to
the ltraon mer as shown in the diagram below.
1
2
1- 2: Power for the lter pump power contactor evaporator
: Filtraon mer
: Power contactor (three-pole or two-pole contactor) for the lter pump motor
: Independent connecng cable for the "heang priority" funcon (not included)
: Heat pump terminal (230V output)
: Fuse
: 230VAC NO relay (not included)
Jointly enabling the heang priority and the mers aects the operang logic of the appliance and
ltraon, see § "2.5 I Jointly enabling the mers and heang priority".