1.5 I Opon connecons
Connecng "Heang Priority" opons:
• Before any work inside the appliance, you must cut the appliance’s electricity supply as there
is a risk of electric shock which may cause material damage, serious injury or even death.
• There is a risk of electrical return current, injuries, material damage and death when
working on terminals 1 to 2.
• Any connecon error with terminals 1 to 2 may damage the appliance and invalidate its
warranty.
• Terminals 1 to 2 are dedicated to the opons and must never be used to directly supply
other equipment.
• Use cables with a secon of at least 2x0.75 mm² , RO2V type and with a diameter between
8 and 13 mm.
Before connecng any opons: remove the seal (above the cable gland) and install the cable gland provided in order to
pass the cables into the appliance.
The cables used for the opons and the power cord must be kept separate (risk of interference) using a collar inside the
appliance just aer the glands.
1.5.1 "Heang priority" opon
• This funcon allows the appliance to start ltraon (connuously or in 5-minute cycles every 120
minutes) in order to detect the water temperature and thus acvate the ltraon + heang unit to
maintain a constant water temperature. The lter pump is thus said to be slaved to the heang system.
Filtraon is kept in operaon or acvated if the pool temperature falls below the desired temperature.
• When making the connecons, make sure that the appliance is powered o, connect a 230 VAC NO relay (not included)
to terminals 1 and 2 (230 V output), then connect the connecon cable (not included) from the output of this relay to
the ltraon mer as shown in the diagram below.
1
2
1- 2: Power for the lter pump power contactor evaporator
: Filtraon mer
: Power contactor (three-pole or two-pole contactor) for the lter pump motor
: Independent connecng cable for the "heang priority" funcon (not included)
: Heat pump terminal (230V output)
: Fuse
: 230VAC NO relay (not included)
• Jointly enabling the heang priority and the mers aects the operang logic of the appliance and
ltraon, see § "2.5 I Jointly enabling the mers and heang priority".