• Each spotlight must be installed at a minimum depth of 10 cm below the
water level.
• The lower cable gland(s) of the juncon box for each spotlight must be
posioned above the pool's maximum water level.
2.1.1 Preparing the pool before installaon
• Install each spotlight in a wall bushing ed with a "sucon port"-type thread of diameter
Ø1.5’’, provided for this purpose during pool construcon (see image ❶).
• The duct or conduit located between the back of the wall bushing and the juncon box
must be waterght because the spotlight is submerged.
• For a opmum pool lighng, each spotlight wall bushing should be posioned 30 to 50 cm
beneath the water level (distance between the top of the lens and the water level).
2.1.2 Installing the appliance
• Slide the power cord through the waterght duct to the juncon box (see image ❷).
• Wind any excess cord away inside the juncon box and conserve sucient length for any
operaons to be performed at a later me.
• Draw the cable and insert the spotlight unl it is ush with the wall bushing (see image ❸).
• If desired, install the white or grey cosmec trim.
• Using the wrench provided, screw the spotlight inside the wall bushing unl ght (see
image ❸). The spotlight's façade must be properly adjusted to the discharge nozzle.
Tip: for easier screwing
• Apply a silicone-based lubricant to the thread.
2.2 I Power supply connecons
• For operaon only with safety isolang transformer properly cered as
being in compliance with the requirements of EN/IEC 61558-2-6 standard.
• Before carrying out work on the appliance, you must rst disconnect the
appliance from the power supply due to the risk of electric shock, which may
cause material damage, serious injury or even death.
• Incorrectly ghtened terminals may cause the terminal unit to heat up and
invalidate the warranty.
• The cord and the juncon box connecon device for the spotlight must not
be completely removed from the duct or pool. There must be enough cord
length in the juncon box to allow the box's spotlight to be removed from
the wall bushing and lied out of the water in order to replace the spotlight's
cartridge.
• Only a qualied and experienced technician is authorised to carry out cabling
work or to replace the power cord.
• The spotlight's power supply must be provided through a 12 VAC transformer (not supplied)
complying with the standards and regulaons in force in the country in which it is installed.
• Electrical protecon: by circuit breaker (D curve) (for rang, see § « 1.2 I Caractérisques
techniques »), with a 30 mA dedicated residual-current protecon system (circuit breaker
or switch) at the head of the line.
• The power supply must correspond to the voltage indicated § « 1.2 I Caractérisques
techniques ».
• The power cord must be protected and insulated from any sharp edges, pressure or hot
elements which may crush, cause abrasion, cuts or other damage to it.
• The electrical wiring must be properly secured from being subjected to unnecessary
movement and strain on connecons.
• To connect the 12 VAC transformer to the juncon box for each spotlight, use the power
cord (RO2V type) adapted for outdoor or buried use (or run the cable into a protecon