If you experience a problem with your LM3, please follow the troubleshooting steps below to restore
performance. Any type of electrical troubleshooting should be performed by a qualified pool professional
or certified electrician. If further assistance is required, contact Zodiac Customer Service at
800-822-7933. Please have your serial number and date of purchase available when you call.
Troubleshooting
Problem Solution
Water looks clean but there is no chlorine • Confirm that pool water is balanced, total alkalinity is
residual reading.
80 - 120 ppm and pH within 7.2 - 7.6 range
Inspect cell for calcium build-up, manually clean
if necessary.
Check for adequate stabilizer (cyanuric acid) levels.
Increase CHLORINE OUTPUT setting.
Increase chlorinator run time.
Verify the pump/filtration system are clean and
operating properly.
Test for salt concentration and add as needed.
Pool is green, walls are slimy or a Backwash the filter, then manually shock the pool to
chlorine odor is evident. destroy algae, bacteria and other contaminants. After
shock treatment, adjust pH to 7.2 - 7.6 ppm and check
for 1 - 3 ppm chlorine level.
Water causing eye and/or skin irritation. Adjust water to proper pH, 7.2 - 7.6 ppm.
Scale formation on pool equipment. Adjust water to proper pH, 7.2 - 7.6 ppm.
Check calcium hardness. Dilute pool with fresh water.
Consult pool professional about sequestering agent.
CHLORINE OUTPUT will not If yellow light in Chlorine Indicator is flashing, the
reach maximum. chlorinator is reversing polarity to clean electrodes. Wait
approx. 5 min. and output should return to normal.
If CHECK SALT light is also on, test water for salt
concentration and add salt if necessary. (Water
temperature below 65° may cause light to illuminate.)
Inspect cell for calcium build-up, manually clean
if necessary.
Installers only: Verify that chlorinator is connected to
220V and incoming voltage is not low. (Raising salt level
can compensate for low voltage,)
No Flow indicator is illuminated. Ensure pool pump and filter are clean.
Make sure valves are open.