MagnaPool™ | Installation Manual
7.2.6 Cover Mode
If the pool is equipped with a compatible electric roller
cover, this can be connected to the controller in order
to automatically reduce hydroxination upon closing
the cover, this is known as Cover mode, see Table 5
and Figure 10 for wiring details. Hydroxination will
resume at the level determined by the programming
upon opening the compatible electric cover.
Cover mode output can be set in the main menu
settings for Low mode. Low can be set from
0%-30% in 10% increments. Programs are still
active while the controller is in Low/Cover mode.
Check that the cover is compatible and connected
to the hydroxinator.
Cover mode will automatically be activated when
the cover is closed. The Cover mode message and
the output percentage are displayed on the screen.
23:04 ON
COVER MODE 10%
Cover mode will stop as soon as the cover is
completely open.
If the controller is equipped with a Dual Link
module we do not recommend connecting the
Cover mode. More specifically, hydroxination is
managed via the Dual Link module. In cases where
the Cover mode is connected in the presence of
a Dual Link module: hydroxination will take place
upon closing the roller cover, even if the ORP
measurement is greater than the setpoint value.
7.2.7 Cold Water Protection
In addition to recording and displaying the water
temperature, the temperature sensor is used to
protect the cell, which is sensitive to cold water.
The temperature displayed on the top left of the
home screen will begin to flash at 15°C.
23:04 ON15°
When water temperature is under or equal to 15°C,
chlorine production automatically switches to the
level defined in Low/Cover mode.
When water temperature is under or equal to 10°C,
chlorine production is stopped. The absence of
hydroxination at this temperature is not hazardous,
as bacterial development is slowed in cold water.
In addition to the flashing temperature, a “LOW
TEMPERATURE” message is alternately
displayed.
Even in cold water temperatures, Boost Mode may
be initiated.
When the temperature goes over 10°C again, the
output percentage will be set to Low/Cover.
When the temperature goes over 15°C again,
hydroxination resumes its level of operation
configured using programs.
7.2.8 Locking the Controller
The controller can be locked, thus deactivating the
buttons on the user interface panel. Simultaneously
press and hold the and buttons for 3
seconds. This function can be accessed from any
screen/menu.
Locking the controller automatically returns the user to
the home screen. To unlock the controller, press and
hold the and buttons for another 3 seconds.
Section 8. Installing and Assigning
Equipment
8.1 Filter Pump
Both single and variable speed pumps can be
connected to and operated by the controller.
8.1.1 Single Speed Filter Pump
NOTE: For any manually-operated variable speed pump
(i.e., any pump that does not have an RS485
communication cable), you must set the pump
conguration to single speed.
1. Disconnect power from the chlorinator and
remove the cover and lower housing.
2. Connect the lter pump to the controller at
the pump connection point in the high voltage
raceway. For Australian installations plug the
lter pump into the socket provided on the
underside of the control unit see Table 5 and
Figure 10 for wiring details.
3. Replace the lower housing and cover.
4. Plug the pump into the socket in the base of
the chlorinator.
8.1.2 Assign Single Speed Pump
1. Press .
2. Use to select “Filter Pump”
then press .
3. Use to select “Single Speed”
then press .
4. The user interface will prompt “Single Speed
Plugd to Device”. Use to select “Yes”
then press .