• The appliance must be stored in a room without any permanent ignion source
(such as open ames, operang gas appliance or operang electric heang).
• No not perforate or incinerate.
• Please note that R32 refrigerant may give o a certain odour.
• In order to comply with the applicable standards and regulaons in terms of the
environment and installaon, in parcular French decree No. 2015-1790 and/or
European regulaon EU 517/2014, a leak test must be performed on the cooling
circuit at least once a year. This operaon must be carried out by a specialist
cered to test cooling appliances.
INSTALLATION AND MAINTENANCE
• The appliance may not be installed close to combusble materials, or the air duct
inlet of an adjacent building.
• With some appliances, it is essenal to t a "protecon grid"-type accessory if the
unit is installed in an area with uncontrolled access.
• During installaon, troubleshoong and maintenance, pipes may not be used as
steps: the pipe could break under the weight, spilling refrigerant and possibly
causing serious burns.
• When servicing the appliance, the composion and state of the heat transfer uid
must be checked, as well as the absence of any traces of refrigerant.
• During the annual appliance sealing test in accordance with applicable legislaon,
the high and low pressure switches must be checked to ensure that they are
securely fastened to the refrigerant circuit and that they cut o the electrical circuit
when tripped.
• During maintenance work, ensure there are no traces of corrosion or oil around
the cooling components.
• Before beginning work on the cooling circuit, stop the appliance and wait for a few
minutes before ng the temperature and pressure sensors. Some elements such
as the compressor and piping may reach temperatures in excess of 100°C and high
pressures with the consequent risk of severe burns.
TROUBLESHOOTING
• All brazing must be carried out by qualied brazers.
• Replacement pipes must always be made of copper in compliance with standard
NF EN 12735-1.
• Leak detecon; pressure test:
- never use oxygen or dry air, risk of re or explosion,
- use dry nitrogen or the mixture of nitrogen and refrigerant indicated on the
informaon plate,
- the test pressure for both the high and low pressure circuits must not exceed
42 bar in cases where the appliance is equipped with the oponal pressure gauge.
• The high pressure circuit pipes are made of copper and have a diameter equal to or
greater than 1’’5/8. A cercate as indicated in §2.1 in compliance with standard
NF EN 10204 must be requested from the supplier and led in the installaon's
technical le.
• Technical data relave to the safety requirements of the various applicable direcves
are indicated on the informaon plate. All this informaon must be recorded in the
appliance's installaon manual, which must be kept in its technical le: model,
code, serial number, maximum and minimum OT, OP, year of manufacture, CE
marking, manufacturer’s address, refrigerant and weight, electrical parameters,
thermo-dynamic and acousc performance.
LABELLING
• The equipment must be labelled so as to specify that it is out of order and that the
EN