Zodiac HPO handleiding

28 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 10 van 28
9
1.5 I Connecng opons
Connecng the "Heang priority" and "remote control" opons:
Before any work inside the appliance, you must cut the appliance’s electricity supply as there is
a risk of electric shock which may cause material damage, serious injury or even death.
There is a risk of electrical return current, injuries, material damage and death when working
on terminals 1 to 2.
Any connecon error with terminals 1 to 2 may damage the appliance and invalidate its
warranty.
Terminals 1 to 2 are dedicated to the opons and must never be used to directly supply other
equipment.
Use cables with a secon of at least 2x0.75 mm² , RO2V type and with a diameter between
8 and 13 mm.
Before connecng any opons: remove the seal (above the cable gland) and install the cable gland provided in order to
pass the cables into the appliance.
The cables used for the opons and the power cord must be kept separate (risk of interference) using a collar inside the
appliance just aer the glands.
1.5.1 "Heang priority" opon
This funcon allows the appliance to start or maintain ltraon (according to seng "P3") in order to detect the
water temperature and thus acvate the ltraon + heang unit to maintain a constant water temperature. The
lter pump is thus said to be slaved to the heang system.
Filtraon is kept in operaon or acvated if the pool temperature falls below the desired temperature.
For the connecon, connect the ltraon mer to terminals 1 and 2 (dry contact, no polarity).
1
2
1- 2: Power for the lter pump power contactor coil
: Filtraon mer
: Power contactor (three-pole or two-pole contactor) for the lter pump
motor
: Separate cable for the "heang priority" funcon
: Heat pump terminal block
: Fuse
Informaon: "P3" seng
P3 = 0 "The lter pump starts and stops in line with the heat pump"
P3 = 1 "Filtering is constantly acve"
Water temperature
< temperature setpoint
Water temperature
> temperature setpoint
Timer OFF
P3 = 0 Filtraon ON Filtraon OFF
P3 = 1 Filtraon ON Filtraon ON
If "Timer" is acve, the lter pump starts and stops in line with the programmed me slots and the
conguraon of the "P3" seng.
Water temperature
< temperature setpoint
Water temperature
> temperature setpoint
Timer ON
P3 = 0
Time slot ON Filtraon ON Filtraon OFF
Time slot OFF Filtraon OFF Filtraon OFF
P3 = 1
Time slot ON Filtraon ON Filtraon ON
Time slot OFF Filtraon OFF Filtraon OFF
1.5.2 "Remote control" opon
This opon enables the appliance's user interface to be transferred in order to control the appliance remotely. To do so,
use the remote control kit.
Connect the signal wire to the pins on the controller.
Pass the wire through the connecon block.
Connect the pins to the electronic board.