37
Con guring the setpoint:
Check that the setpoint has been set to its maximum on the hea ng system.
Con gure the desired water temperature setpoint. The default value is 28°C. This value can be set between 15 and 32°C.
In this case, the temperature sensor of the chlorinator measures the water temperature.
• Press . Browse the menu using the bu ons. Press to con rm.
Depending on the hea ng system (in par cular when using a heat pump), there may be a delay of a few
minutes between the  me the chlorinator closes the AUX2 contact to ac vate the hea ng system and the
e ec ve start-up of the hea ng system (heat pump compressor).
The chlorinator displays the measured water temperature:
hea ng stopped
hea ng in opera on
The water temperature is measured by the water temperature sensor of the chlorinator:
- If the measured water temperature falls below the setpoint value by 1°C or more (e.g. 28°C -1°C
= 27°C), the relay is closed to ac vate the hea ng system.
- If the measured water temperature is equal to or greater than the setpoint value by 1°C or more
(e.g. 28°C +1°C = 29°C), the relay is opened to deac vate the hea ng system.