12

 

 
Rinse the  p of the pH sensor with tap water.
Shake it to remove excess water.
3.3.1 Calibra ng pH 7
Immerse the sensor in pH 7 bu er solu on.
Press and hold the
bu on for 5 seconds un l is displayed, then
,
Press
, the progress bar is displayed:
A� er about 60 seconds the pH sensor reliability measurement is displayed.
Depending on the message displayed, perform the corresponding opera ons:
Message
Ac on(s) turn o the appliance using the master switch
0-1
replace the bu er solu on and/or the pH
sensor
restart calibra on
con nue calibra on
Rinse the  p of the pH sensor with tap water.
Shake it to remove excess water.
3.3.2 Calibra ng pH 4
Immerse the sensor in pH 4 bu er solu on.
Press the
bu on to display ,
Press
, the progress bar is displayed: ,
A� er about 30 seconds the pH sensor reliability measurement is displayed.
Depending on the message displayed, perform the corresponding opera ons:
Message
Ac on(s) turn o the appliance using the master
switch 0-1
replace the bu er solu on and/or the pH
sensor
restart calibra on
press to complete calibra on
Rinse the  p of the pH sensor with tap water.
Shake it to remove excess water.
Fit the sensor back onto its holder.
The sensor measurement is more accurate if the calibra on is performed at 2 points (pH7 and
pH4) rather than at a single point (pH7)