User Issue Possible Cause Suggested Solution
The cleaner is not
moving.
The cleaner may not be
charged.
The outlet the charging station is connected to is not
supplying electrical power. Check that the outlet to
which the charging station is connected isreceiving
electricity.
Cycle not started. Remove from water and start the cleaner using
theslider by sliding and releasing to the right or use
the App.
Reset needed. Turn off the cleaner using the slider by sliding to the
left and hold for 20 seconds. Then, place the cleaner
on the charging station to wake it up. If the problem
is not resolved, contact your local retailer to request
a diagnostic review or contact Technical Support at
1300 763 021 for Australia or 0800 807 665 for New
Zealand.
The cleaner does not fully
charge.
Dirty charging contacts. If the cleaner does not charge after 4 hours of
charging, clean the charging contacts on both cleaner
and charging station with a cloth and non salt water.
Dry the cleaner before putting on the charging station
after each cycle use. If the underside of charging
station is blinking green it will need to be replaced.
The cleaner is not
cleaning the pool
effectively.
Filter canister is full or dirty. Dispose of debris and thoroughly clean the filter
canister with mild soap and a soft brush. Then,re-
submerge the cleaner (see Clean the Filter Canister).
Brushes are worn.
Check the wear indicator(s) (see Replacing Wear Parts).
The cleaner is not fully
charged.
Charge the cleaner.
The cleaner does not
collect debris or go
forward.
Debris jamming traction
motor.
Remove any debris in the front brush area.
7.2 Charging Station Behavior
User Issue Cleaner Behavior Charging Station Behavior Suggested Solution
The cleaner
will not
charge
The battery LED on the
cleaner does not blink
when the cleaner is on the
charging station.
The charging station is
connected but the LED under
the station is off or blinking
(instead of green) when the
cleaner is placed on it.
The cleaner is not positioned
correctly on the charging
station.
Clean charging contacts on
the cleaner and the charging
station with a cloth and fresh
non salt water.
The charging station is faulty,
contact your retailer for a
diagnostic review or contact
Technical Support at 1300 763
021 for Australia or 0800 807
665 for New Zealand.
The LED under the charging
station is green when the cleaner
is placed on it.
The battery LED on the
cleaner blinks red 4 times
when the cleaner is on the
charging station.
The charging station is
plugged into a GFCI outlet.
The charging station LED is
green when the cleaner is
placed on it.
The charging station LED
is red when the cleaner is
placed on it.
Clean charging contacts on
the cleaner and the charging
station with a cloth and fresh
non salt water.
The battery LED on the
cleaner blinks orange for
a few seconds or minutes
then switches to solid
green when cleaner is on
the charging station.
Remove the cleaner from the
charging station. If the battery
LED on the cleaner turns
off instead of indicating the
charge level the battery needs
replacing.