6.2 I Inspecng and cleaning the electrodes
The appliance is equipped with a smart polarity inversion system designed to prevent the electrode plates
from scaling. The polarity reversal me can be modied, see § “4.3.4. “Reverse direct”: Reversal adjustment
for cell cleaning”. However cleaning may be required in regions where the water is very hard.
• Turn o the appliance and the ltraon system, close the isolaon valves, remove the protecon cover and discon-
nect the cell power cable.
• Unscrew the ghtening ring and remove the cell. The ring is crenelated thus allowing a lever to be used in the event
of it jamming (see gure
).
• Submerge the part containing the electrode plates in a suitable recipient containing a cleaning soluon (see gure
).
• Leave the cleaning soluon to dissolve the scale deposit for about 10 minutes. Dispose of the cleaning soluon at
an approved waste recycling site. Never pour into the rainwater drainage system or into the sewers.
• Rinse the electrode using clean water and put it back on the cell xture collar (there is an alignment foolproofer).
• Ret the ghtening ring, reconnect the cell cable and ret the protecve cover.
• Re-open the isolaon valves and restart the ltering system and appliance.
If you are not using a commercially-available cleaning soluon, you can make your own by
carefully mixing 1 part hydrochloric acid with 10 parts water. (Cauon: always pour
the acid into the water and not the opposite and wear suitable protecve equipment).