2.5 I Installing the control box
2.5.1. Placement of the control box
• The control box must be installed in a dry venlated technical room protected against frost, with no pool
maintenance products or similar products stored nearby.
• The control box must be installed at a distance of at least 3.5 m from the outside edge of the pool. Always
comply with the installaon codes and/or laws applicable at the place of installaon.
• It must not be installed more than 1.6 metres from the cell (maximum cable length).
• If the box is xed to a post, a waterght panel must be xed behind the control box (350x250 mm
minimum):
- Secure the mounng (provided) to the wall or to the waterght panel using screws or wall plugs (not
provided) (gure
).
- Clip the top of the control box into the mount (gure ).