13
2.5.2 Iden fying the func ons to be connected
Terminal
block
messages
Type
Cable
clamp
Func ons eXO® (iQ) GenSalt OT
With pH Link or
Dual Link
SENS Input -
Connec on for the control board
for pH Link and Dual Link modules
/ /
PUMP Input -
Connec on for the pH regula on pump
for pH Link and Dual Link modules
/ /
CELL Output 1 Connec on for the electroly c cell
UI Output - Connec on for the display
TEMP Input 3 Connec on for the temperature sensor /
Flow Input 2 Connec on for the  ow switch
iAL RS485 Input 4 Func on not used – do not wire / / /
VSP RS485 Output 5
Connec on dedicated to controlling the
Zodiac® variable-speed  lter pump
/
/- Func on not used – do not wire / / /
COVER Input 7
Connec on for the roller shu er/cover for
automa cally managing the LOW func on
SLAVE Input 8
Connec on for an external appliance for the
ON/OFF control of the chlorinator (automa c
regula on, etc.)
/
AUX 2 12-
24V
Output 9
Connec on dedicated to the ON/OFF control
of a low-voltage device. Connec on used to
control a hea ng system. This connec on
does not power the device: it manages the
ON/OFF func on.
AUX 1 230
V
Output 10
Connec on dedicated to the ON/OFF control
of a high-voltage device. This connec on
does not power the device: it manages the
ON/OFF func on.
/
PUMP
230V
Output 11
Connec on dedicated to the power supply to
the pool  lter pump.
MAINS Input 12
Mains power supply to the appliance
110-240 VAC - 50/60 Hz
: Connec ons made during manufacture : Mandatory connec ons to be made : Func on to be connected (op onal)