8
❷ Installing the salt water chlorinator
2.1 I Installing the cell
The cell must be installed on the piping a er the ltra on system, a er any measurement sensors, and
a er any hea ng system.
Installing the chlorinator only
(Example with eXO® (iQ))
Installing the chlorinator + op onal module
(Example with eXO® (iQ))
The cell must always be the last element placed on the pool return pipe (see diagram).
It is always recommended to install the cell on a by-pass. This assembly is MANDATORY if the
ow is in excess of 18 m³/hour to avoid head loss.
If you installed the cell on a by-pass, it is recommended to t a check valve downstream from
the cell instead of a manual valve, to avoid any risk of incorrect con gura on which could
result in poor circula on inside the cell.
2.1.1 eXO® (iQ) cell
12.5 cm
21.5 cm
32 cm
11 cm
15.5
cm
21.5
cm
11 cm
21.5 cm
Make sure that the cell is placed HORIZONTALLY. The water should ow from the electric connec ons
towards the opposite side.
Use the screw-on  ngs to  x the cell to the pipes.
For Ø63 mm pipes, glue them directly to the screw-on ngs. For Ø50 mm pipes, use glue-on PVC adapters
of the corresponding diameter (grey models; the white models are for 1 ½’’ UK pipes).
Connect the cell power cord following the wire colour codes (red, black and blue connectors) and then re t
the protec ve cap. The two red wires can be connected to one or the other red terminals on the electrode.