Zodiac Chlor Expert handleiding
Handleiding
Je bekijkt pagina 20 van 21

18
5.2 I Displays
Message Possible causes Solu ons
"Level Low"
• Corrector product container
empty
• Replace the corrector product container
• Floater blocked • Check that the white fl oater on the suc on
cane is in working order
• Level sensor cut o • Change the suc on cane
"OFA Alarm"
First step of the ac vated over
feed safety mechanism ( me >
75%)
• Press
to stop the alarm
• Check the sensor and/or the pool chlorine
level
"OFA Stop"
Second step of the ac vated
over feed safety mechanism
( me = 100%)
• Press
to stop the alarm
• Check the sensor and/or the pool chlorine
level
"OFA Test"
ORP sensor measurement test
if the "OFA Stop" was ac vated
during the previous ltering
cycle
• Wait for the end of the procedure (1 hour)
then check the sensor and/or the pool
chlorine level
"Filtering"
• Filtering stopped • Start and/or check the ltering
• Incorrect connec on • Check the electrical connec ons
"465 Sensor Fail"
• Bu er solu on defec ve • Check that the solu on used is 465 mV
• Use a new bu er solu on
• The sensor is dirty or defec-
v e
• Restart calibra on
• Check the condi on of the sensor p
• Check the condi on of the sensor's porous
coa ng
• Clean the sensor by dipping its p into a 10 %
hydrochloric acid solu on
• The sensor is worn • Replace the ORP sensor
"Parameter Error"
Parameter error
• Press
to cancel the error
• Replace the printed circuit board
If the problem con nues, contact your retailer.