Zodiac Chlor Expert handleiding

21 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 16 van 21
14
3.6.3 "Set point" menu
2 methods for adjus ng the set point:
see § "3.6.1 "Se ngs" menu"
Or:
Press when the appliance is running: ,
Press and hold and adjust the set point using the and keys.
Release the key to exit.
3.6.4 "Boost" menu
Do not set "Boost" mode to operate over a long period (> 10 minutes) if the volume of the
pool is low (< 40 m³).
This is used to set the "Boost" mode opera ng  me.
By default, the "Boost" mode is set to 10 minutes (which corresponds to 250 mL of injected corrector product).
3.6.5 "OFA � me" menu
The appliance is  ed with a safety mechanism to avoid any risk of correc on product overdose, for example
in the event of a problem with the sensor. This safety mechanism, called the "OFA" (=Over Feed Alarm),
pauses the appliance if it has not reached the set point within a given me limit. A high value is strongly
recommended to avoid any unplanned and/or unjus ed triggering (a se ng in excess of 4 hours is suitable
for large pools and/or highly used pools).
The over feed safety mechanism operates in two main steps:
ashes a� er 75% of the programmed me has elapsed without having
reached the set point
is displayed when the me has elapsed. The appliance then switches to
safety mode.
If ltering stops and restarts (=daily cycles) while the appliance is in "OFA Stop" status, the appliance will
ac vate an "OFA Test" mode for 1 hour to make sure that the measurement from the sensor is correct.
On comple on of this "OFA Test" mode:
- if the set point has been reached = the appliance remains in normal mode
- if the set point has not been reached: the appliance switches to "OFA Alarm" mode with an injec on of
corrector product
- if the set point has s ll not been reached a� er the "OFA Alarm" mode is complete (=25% of total OFA
set me), the appliance switches to "OFA Stop" safety mode and will remain in this state un l manual
interven on.
To reset this safety measure and restart the appliance, press the
key. First make sure that the sensor is
in good condi on and is calibrated.
Special over feed safety func on:
In order to prevent false alarms just a� er the appliance is installed, the over feed safety can be deac vated
for 24 or 48 hours:
Press
, and at the same me to deac vate the safety mechanism for 24 hours
Press , and at the same me to deac vate the safety mechanism for 48 hours

Bekijk gratis de handleiding van Zodiac Chlor Expert, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkZodiac
ModelChlor Expert
CategorieNiet gecategoriseerd
TaalNederlands