TROUBLESHOOTING
SYMPTOM POSSIBLE CAUSE POSSIBLE SOLUTION
Igniters are sparking
but burners are
not igniting.
Gas shut-off valve is in the
“OFF” position.
Turn shut-off valve to the
“ON” position.
Cooktop burners
will not stay lit and
auto reignition is
not working.
Spark tip or igniter failure. Contact ZLINE customer service.
The flames have
suddenly gone out.
A draft or spill has
extinguished the flame.
Turn the burners off, cleaning the
burners and cooktop area. Once
clean, reignite top burners.
Burner flame goes out
at low setting
Low gas pressure. Contact gas company.
Air intake holes around
burners are obstructed.
Remove obstruction from air
intake holes.
Low flame adjustment may
be set too low.
Readjust.
Top burners do
not light or do not
burn evenly.
Plug on appliance is not
completely inserted in the
electrical outlet.
Make sure the unit is properly
connected to the power supply.
Burner holes on the side of
the burner may be clogged.
Remove the burner heads
and clean them. Check the
electrode area for burned-on
food or grease.