Zipper ZI-FS250-1200 handleiding
Handleiding
Je bekijkt pagina 22 van 31

OPERATION
ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at 22
ZI-FS200-720 | ZI-FS250-1200
14.3 Electrical connection
Dangerous electrical voltage!
Risk of injury due to dangerous electrical voltage!
The machine may only be connected to the power supply and the associated
checks carried out by a qualified electrician or under the instruction and
supervision of a qualified electrician!
• Check, whether the neutral connection (if existing) and the protective grounding
function properly.
• Check, whether the supply voltage and the frequency correspond to the
specifications of the machine.
Deviation of the supply voltage and frequency!
A deviation from the value of the supply voltage of ±5 % is permissible.
A short-circuit fuse must be provided in the power supply system of the machine!
• Use a supply cable that fulfils the electrical requirements (e.g. H07RN, H05RN) and
take the required cross-section of the supply cable from a current carrying capacity
table. Pay attention to the measures for protection against mechanical damage.
• Make sure that the power supply is protected by a residual current circuit breaker.
• Connect the machine only to a properly grounded outlet.
• When using an extension cable, make sure that the dimension matches the
connected load of the machine. The connection power can be found in the technical
data, the correlation of cable cross-section and cable lengths can be found in the
technical literature or obtain information from a specialist electrician.
• A damaged cable must be replaced immediately.
NOTE
Operation is only permitted with residual current device (RCD) with maximum
residual current of 30 mA.
15 OPERATION
Only operate the machine when it is in a perfect condition. Before each operation, a visual
inspection of the machine must be carried out. Safety devices and operating elements must be
checked carefully. Check screw connections for damage and tight fit.
15.1 Operating instructions
Wet cutting process!
To avoid dust hazard the machine must only be used in wet operation.
Fill the water tank to 75% with water.
Check all hose connections, pump and pump connection.
15.2 Handling
15.2.1 Switch the machine on and off
Switch on
• Press the switch-on button (I).
Switch off
• Press the switch-off button (0)
WARNING
NOTE