Zeiss Lightweight Zoom LWZ.3 handleiding

26 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 21 van 26
19
Correcting the Flange Focal Distance
1. Remove the ZEISS LWZ.3 from the camera.
2. Follow the steps of chapter Detaching a Mount.
3. Determine the total thickness of the shims that already lay in the lens groove.
4. Increase or decrease the total shim thickness according to the Shimming Table in the appendix.
Any combination of shims is possible to achieve the required thickness and therefore the desired flange
focal distance. Always use the closest possible combination of shims.
Example: Using a ZEISS LWZ.3 with an EF mount, scaled in feet and a test chart at a test distance of 10 ft,
an actual distance of 10 ft 1´ is measured. Due to the shimming tables, you add a light blue shim 0.03 mm
to the total thickness of the shims.