3.18 Extended “XTEST”
This command is used for installation and testing and requires the use of a H-4191 Sidekick
interface and a PC. This command causes the H-4161 to display a listing of the H-4161's current
settings. This is not compliant with the SDI-12 specification and is not used with data loggers.
An example of an “XTEST” printout is shown below:
H-4611 Settings:
Module Mode = MONITOR
Monitored Address = Z
Monitored Parameter = 1
AutoScan Address = 0
AutoScan Command = 0
Measure Rate (sec)= 0
Max data (@20mA) = 20.0
Min data (@4mA) = 4.0
3.19 Extended “XHELP”
This command is used for installation and testing and requires the use of a H-4191 Sidekick
interface and a PC. This command causes the H-4161 to display a listing of the supported SDI-
12 commands. This is not compliant with the SDI-12 specification and is not used with data
loggers.
3-18 SDI-12 Command and Response Protocol
H-4161