Pipe dimension and ways of installation
Allowed length and height drop
Please refer to refrigerant pipe connection for detail
Outdoor pipe dimension and ways of install (in sequence of cooling capacity
H
Outdoor Unit
Indoor Unit
Longest PipeL
Oil Return
Height Drop5m
Remove objects and water
Additional refrigerant charge
Liquid pipe diameter
Additional charge for 1m pipe(R32)
Before installing refrigerant pipe, please clean the pipe in case of foreign objects.
Use high-pressure nitrogen to clean the pipe instead of outdoor refrigerant.
The additional charge is base on the diameter and length of outlet/inlet liquid type .
This AC has been charged with that for 5m pipe, those beyond 5 m should recharge as follows.
1/4
0.016kg
0.040kg
1/2
0.096Kg
REFRIGERANT PIPE INSTALLATION
Copper Pipe for Air ConditionerPipe Material
Size(mm)
Gas side
Liquid side
Model
24
12/
18K
K
30/36/42/48/55K
f6.35(7/16inch)
f9.52(5/8inch)
f12.7(3/4inch)
f6.35(7/16inch)
f15.88(7/8inch)
f9.52(5/8inch)
Allowed value
Longest pipe (L)
50m
25m
Height drop between indoor
and outdoor unit H
Maximum
height drop
Conventional pipe, cooling capacity36000-42000Btu/h
Allowed value
Longest pipe(L)
30m
15m
Height drop between indoor
and outdoor unit
Maximum
height drop
Conventional pipe, cooling capacity18000~30000Btu/h
3/8
Allowed value
Longest pipe(L)
60m
30m
Height drop between indoor
and outdoor unit
Maximum
height drop
Conventional pipe, cooling capacity48000~55000Btu/h
19