Handleiding
Je bekijkt pagina 27 van 32

smooth surface
●
improper expanding
shaper
downwards
union pipe
pipe
expander
pipe
C: Put on suitable insulating pipe
A(mm)
Max Min
1.3 0.7
1.6 1.0
1.8 1.0
2.4 2.2
22
the length is equal
hard
mold
Outer diameter
(mm)
leaning
damaged
crack uneven
surface thickness
Φ6 - 6.35(1/4")
Φ9 - 9.52(3/8")
Φ12-12.7(1/2")
Φ15.8-16(5/8")
B: Remove the burrs
D: Put on the union nut
●
E: Expand the port
●
●
pipe and outdoor valve;
install the union nut on
the pipe.
F: Inspection
burrs from getting into the pipe.
pipe
32/23 43/26
27/- 24/18
Working temperature range
Outdoor side
DB/WB(°C)
Maximum
Maximum
NOTE
Remove the burrs with shaper and prevent the
NOTICE
cooling
"A" is different according to the diameter, please refer
to the sheet below:
●
heating
●
For some models:
Indoor side
DB/WB(°C)
Expand the port with expander.
GWH09AFC-K6DNA2F/I(LC)、
GWH12AFC-K6DNA2F/I(LC)
GWH09AFC-K6DNA3F/I、 GWH12AFC-K6DNA3F/I
GWH09AFC-K6DNA5F/I
、
GWH12AFC-K6DNA5F/I
GWH18AFD-K6DNA2I/I
(LC)
、
GWH18AFD-K6DNA5I/I(LC)
GWH24AFE-K6DNA5I/I、
GWH24AFE-K6DNA2I/I(LC)
Remove the union nut on the indoor connection
Check the quality of expanding port. If there is
32/23 50/26
27/-
Indoor side
DB/WB(°C)
Outdoor side
DB/WB(°C)
Maximum
30/18
Maximum
NOTE
cooling
●
heating
any blemish, expand the port again according to
the steps above.
The operating temperature range (outdoor tempera-
ture) for Low-temperature cooling only unit is -15°C
~43°C ; for Low-temperature heat pump unit is -22°C
~43°C.
The operat
ing temperature range (o
utdoor t
empera-
ture) for Low-temperature cooling only unit is -15°C
~50°C ; for heat pump unit is -15°C~50°C.