Precautions for rack mounting
The guaranteed operating temperature range for this device is 0 to 40 °C. When multiple DME7 devices are
mounted and operated on a standard EIA rack, it is not necessary to leave space between them. When this
device is mounted on a standard EIA rack together with other devices, heat generated from those devices may
impair performance due to the elevated temperature in the rack. In order to prevent heat from building up inside
this device, be sure to mount it in a manner that satisfies the following conditions.
• When mounted together with a power amplifier or other devices that tend to generate heat, leave at least
1U of space between this device and other devices. In addition, in order to ensure adequate ventilation,
install vented panels at those spaces or leave the spaces open.
• This device is designed to intake air at the front and exhaust it at the rear, so do not install it together with
other devices that intake air at the rear and exhaust it at the front.
• Leave the rear of the rack open and the rack positioned at least 10 cm away from the wall and ceiling. If
the rear of the rack cannot be left open, use a commercially available fan kit or other forced air ventilation
system. If a fan kit is installed, note that closing off the rear of the rack can improve heat dissipation in
some cases. For details, refer to the instruction manuals for the rack and fan kit.
Introduction
6 | DME7 Reference Manual