Operating Instructions Operating Instructions
PROBLEM CAUSE REMEDY
The unit does not
start when pressing
Not plugged in / Plug or socket is damaged. Plug in or replace the power or socket.
A fuse is blown or broken. Replace the fuse (3.15A/250AC).
The room temperature is lower than the set temperature.
(Cooling mode)
Reset the temperature.
Not cool enough
The doors or windows are not closed. Make sure all the windows and doors are closed.
There are heat sources inside the room. Remove the heat sources if possible.
The exhaust air hose is not connected or blocked. Connect or clean the exhaust air hose.
Temperatu
re setting is too high. Reset the temperature.
The air inlet is blocked. Clean the air inlet.
High noise level
air conditioner
It is normal.
If you are having trouble with your portable air conditioner, please refer to troubleshooting section below.
If nothing of the below works, please contact your retailer for servicing of your Air Conditioner.
Error Codes CAUSE REMEDY
E2 Code
Room temperature sensor failed or is damaged. Replace room temperature sensor.
E3 Code
Evaporator temperature sensor failed. Replace evaporator temperature sensor.
E4 Code
Water tank full. Please empty the water tank.
*This marking indicates that this product should not be disposed of with other household wastes throughout the EU. To prevent possible
harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of
material resources. To return your us device, please use the return and collection systems or contact the retailer where the product was
purchased. They can take this product for environmentally safe recycling.
*Used batteries must not be disposed of through household garbage,since they might contain toxic elements and heavy metals that can be
harmful to the environment and human health. Return empty batteries to an appropr
iate recycling facility.
NOTE!
Register at www.warranty-woods.com
and read about how to get
extended warranty. Please visit
www.woods.se for more information.
Recommended limits for use
The best operating ambient temperature
for cooling is 17-35 °C,
Fuse Parameter: φ5.0x20mm
3.15A, 250Vac.
Cooling/Heating capacity 2000 W/1500W 2600 W/2000W
Cooling/Heating Power consumption 750 W/600W 950 W/750W
Airflow: 350 m
3
/h 350 m
3
/h
Energy class A A
Dehumidification 19 L / 24h 24 L / 24h
Temperature setting 15-31°C 15-31°C
Working temperature 16-43°C 16-43°C
EER 2,6 2,7
Length of air exhaust hose 1,5 m 1,5 m
Diameter of the air exhaust hose pipe 155mm 155mm
Refrigerant gas R290/100g R290/160g
Noise level in decibels 51dB 51dB
Weight 22.5kg 24.5kg
Dimensions in mm, L x Wx H 355x350x700 355x350x700
TECHNICAL DATA
*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as
temperature, ventilation, and humidity.
NOTE!
Register at www.warranty-woods.com
and read about how to get an extended
warranty. Please visit www.woods.se for
more information.
Guarantees
2 years consumer warranty against production faults. Please note that the warranty is only valid upon
the production of the receipt. The warranty is only valid if the product is used in accordance with
the instructions and security warnings expressed in this manual. The warranty does not cover any
damages caused by improper handling of the product.
NOTE: The 2 years warranty only applies for consumers and not to
commercial use of the unit.
WIFI Smart Home DuoC Milan 9K
A
WIFI Smart Home DuoC Milan 7K
A
Bekijk gratis de handleiding van Wood's AC Milan 7K WIFI Smart Home Duo, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Wood's |
Model | AC Milan 7K WIFI Smart Home Duo |
Categorie | Airco |
Taal | Nederlands |
Grootte | 15596 MB |