MALFUNCTION
POSSIBLE CAUSE
MEASURE
THE APPLIANCE IS UNSTABLE.
1. Screws are not firmly tightened.
1. Tighten the screws.
2. The mounting bracket / mounting
plate is not fixed firmly.
2. Fix the mounting bracket /
mounting plate properly.
THE ILLUMINANTS DO NOT WORK.
1. The extractor hood is not switched
on.
1. Switch on the extractor hood.
2. One or all illuminants are defective.
2. Replace the defective illuminants. See
chapter « REPLACING OF THE LED
ILLUMINANTS ».
PLEASE NOTE: LED illuminants must
be replaced by a qualified professional
(electrical engineer) only.
If the appliance shows a malfunction not noted on the schedule above or if you
have checked all items on the schedule but the problem still exists, please contact
the aftersales service.
IF THE HOOD DOES NOT WORK PROPERLY AND / OR YOU CAN HEAR
INCREASED OPERATING NOISE, CHECK THE SCHEDULE BELOW.
IN EXTRACTION MODE
Incorrect dimension of the air duct.
Obstruction in the air duct.
The diameter of the air duct from hood to wall-box inclusive should be 120/150
mm (see chapter « TECHNICAL DATA »); otherwise, the capacity of the motor may
be decreased.
If you have installed a fly screen on the wall-box, the air vent may be obstructed.
Check by removing the fly screen.
If the cover panel of the wall box is equipped with firm and slanted slats, the air
vent may be obstructed. Check by removing the cover panel.
Install a cover panel with moveable slats, which do not obstruct the air vent.
Check condition and cleanliness of the filters.