INSTALLATION OF THE CHIMNEY / RECIRCULATION MODE
The air vents (M) of the upper chimney (K) must face upwards and not be covered
by the lower chimney (L). S. fig. below. The air vents in the inner chimney are not
available on all appliance models. If your appliance model does not have air vents
in the inner chimney, you can skip this poin
2.2 Important installation instructions: extraction mode
WARNING! Do not lead the exhaust air into a chimney which is used
for extracting exhaust air of appliances operated by gas or other
combustibles.
➢ For extracting the exhaust air always observe the current legal regulations.
➢ The diameter of the exhaust hose must meet the diameter of the connecting ring.
➢ If your appliance is equipped with a carbon filter, remove the carbon filter before
you operate the appliance in the extraction mode. The carbon filter should be
used in the recirculating mode only.
➢ The exhaust duct should be as short and straight as possible. The diameter of the
exhaust hose should be at least 120 / 150 mm (look at chapter TECHNICAL DATA).
Otherwise, you have to expect increased noise and decreased performance of
your appliance.
➢ The proper maximum bending angle outwards is 120°.
➢ Use smooth tubes or flexible, non-inflammable exhaust hoses only.
➢ When the exhaust duct is connected horizontally, a minimum falling gradient of
1 cm/m or an inclination of 2° is required. Otherwise, condensate will get into
the motor of the hood.
➢ When an exhaust duct is used, the ending of the exhaust hose must be adjusted
into the direction of flow.
➢ If the exhaust duct passes through cool areas (e.g., an attic), a temperature
gradient may occur in the different parts of the exhaust duct so condensate will
be generated. Proper insulation of the corresponding parts of the exhaust duct
will then be needed. Equip such an exhaust duct with a condensate trap if need
be.
➢ Depending on the appliance model the hood is equipped with one (top) or
two (top, back) outlets. The idle outlet is covered by a plastic cap. You can remove
this cap by turning it anticlockwise. Use the cap to cover the idle outlet.
2.3 Minimum distances
❖ The minimum distance between the extractor hood and an electric hob must be
at least 45.00 cm.