Installation Requirements
A minimum 2" (51) is required from the bottom of the
cooktop to combustible materials. If the cooktop is installed
above an oven, a minimum of
1
/4" (6) is required between
the units. Refer to the illustration on page 6 for additional
minimum clearances.
WARNING
Failure to locate the cooktop without proper clearances
will result in a re hazard.
SPECIFICATIONS
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustration on
page 6. A separate circuit servicing only this appliance is
required. A ground fault circuit interrupter (GFCI) is not
recommended and may cause interruption of operation.
When multiple cooktops or modules are installed side by
side, each unit must have its own separate recommended
electrical circuit.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 6'
(1.8 m)