wolfappliance.com | 5
Specifications
Installation Requirements
Follow all minimum clearances to combustible surfaces.
For48"(1219)modelsonly,twoseparateelectrical
supplies are required. For ease of installation, the
receptacles should be positioned with the grounds facing
each other to prevent cord interference.
Electrical Requirements
Installation must comply with all applicable electrical
codes.
Locate the electrical supply flush with the wall or floor. A
separate circuit servicing only this appliance is required.
If a power supply cord is used, the cord must be
designated for use with ranges and rated for 240 V, 50
amps, and must include 3 or 4 conductors. A 4-
conductor cord is required for installations where
grounding through the neutral is prohibited.
Performance may be compromised if the electrical supply
is less than 240 volts.
IMPORTANT NOTE: Two separate electrical services are
required for 48" (1219) models.
ELECTRICAL
REQUIREMENTS
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service* 50 amp dedicated circuit
* Two for 48" (1219) models.