No Wall Studs at End Holes (Figures 1 and 2 in
Find the Wall Stud(s) section)
NOTE: The mounting plate must be secured to the wall on at
least 1 wall stud as well as at both ends.
1. With the support tabs of the mounting plate facing forward,
insert 3/16-24 x 3" round-head bolts through both end holes of
mounting plate.
2. Start toggle nuts on bolts from the back of the mounting plate.
Leave enough space for the toggle nuts to go through the wall
and to open.
A
B
C
A. 3/16-24 x 3" round-head bolt
B. Mounting plate
C. Spring toggle nut
3. Position mounting plate on the wall.
4. Push the 2 bolts with toggle nuts through the drywall, and
finger tighten the bolts to make sure toggle nuts have opened
against drywall.
A
B
C
D
A. 3/16-24 x 3" round-head bolt
B. Mounting plate
C. Spring toggle nut
D. Drywall
5. Insert lag screw(s) into the hole(s) drilled into wall stud(s) in
Step 2 of “Installation for No Wall Studs at End Holes” in the
“Drill Holes in Rear Wall” section.
6. Check alignment of mounting plate, making sure it is level.
7. Securely tighten all lag screws and bolts.
Wall Stud at One End Hole (Figure 3 in Find the
Wall Stud(s) section)
1. With the support tabs of the mounting plate facing forward,
insert a 3/16-24 x 3" round-head bolt through the end hole that
fits over the 5/8" (16 mm) hole drilled in step 3 of “Installation
for Wall Stud at One End Hole” in the “Drill Holes in Rear Wall”
section.
2. Start a toggle nut on the bolt from the back of the mounting
plate. Leave enough space for the toggle nut to go through the
wall and to open.
3. Position mounting plate on the wall.
4. Push the bolt with toggle nut through the drywall, and finger
tighten the bolt to make sure toggle nut has opened against
drywall.
5. Insert a lag screw into the remaining end hole.
6. If installing on a second wall stud, insert a lag screw into the
other hole drilled in Step 2 of “Installation for Wall Stud at One
End Hole” in the “Drill Holes in Rear Wall” section.
7. Check alignment of mounting plate, making sure it is level.
8. Securely tighten the lag screw(s) and bolt.
Rotate Blower Motor
This section include wall and roof venting installation, both venting
installation need rotate blower motor, select one ventilation type
before install the microwave oven. And follow the propriated
instruction to rotate the blower motor. If for recirculation
installation, no need to rotate the blower motor, this section can be
skip.
Rotate Blower Motor for Wall Venting Installation
1. Remove screws attaching damper plate to back of microwave
oven, set the screws aside.
A
B
A. Damper plate
B. Screw
2. Turn and hold the damper plate vertically as shown.
A
A. Damper plate
3. Remove 2 blower screws attaching blower motor to the
microwave oven, and set aside.
A
A. Blower screws