INSTALLATION REQUIREMENTS
Electrical Requirements—All Models
The electrical ratings for air conditioner are listed on the model
and serial number label. The model and serial number label is
located on the right-hand side of the air conditioner cabinet.
Requirements" sections. Follow the requirements for the type of
plug shown in these sections.
Recommended Grounding Method
This air conditioner must be grounded. This air conditioner is
equipped with a power supply cord having a grounded 3 prong
plug. To minimize possible shock hazard, the cord must be
plugged into a mating, grounded 3 prong outlet and grounded
in accordance with all local codes and ordinances. If a mating
outlet is not available, it is the customer’s responsibility to have a
installer. It is the customer’s responsibility:
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70—
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269
4
8k
Voltage(V)
Current(A)
Fuse
115 V (103 min - 127 max)
0 - 10 A
15 amp time-delay fuse or
circuit breaker
10k
115 V (103 min - 127 max)
0 - 12A
15 amp time-delay fuse or
circuit breaker
12k
115 V (103 min - 127 max)
0 - 13 A
15 amp time-delay fuse or
circuit breakerr