Make sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/NFPA 70-
latest edition or CSA Standards C22.1-94, Canadian Electrical Code,
Part 1 and C22.2 No.O-M91-latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association 1 Batterymarch Park
Quincy, MA
02169-7471
CSA
International
8501 East Pleasant Valley Road Cleveland, OH 44131-5575
Before You Make the Electrical Connection:
To properly install your cooktop, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
A 4-wire or 3-wire, single phase, electrical supply is required
on a separate circuit as indicated by the tables below, fused on
both sides of the line.
240 V, 60 Hz, AC only electrical supply:
Cooktop Configuration Circuit
4 Cooking Zones 40 A
5 Cooking Zone 50 A
208 V, 60 Hz, AC only electrical supply:
Cooktop Configuration Circuit
4 Cooking Zones
40 A
5 Cooking Zone 60 A
The cooktop should be connected directly to the junction box
through flexible, armored or nonmetallic sheathed, copper
cable. The flexible, armored cable extending from the fuse box
or circuit breaker box should be connected directly to the
junction box.
Locate the junction box to allow as much slack as possible
between the junction box and the cooktop so that the cooktop
can be moved if servicing becomes necessary in the future.
Do not cut the conduit. The length of conduit provided is for
serviceability of the cooktop.
A UL listed or CSA approved conduit connector must be
provided at each end of the power supply cable (at the cooktop
and at the junction box). A listed conduit connector is already
provided at the cooktop.
If the house has aluminum wiring, follow the procedure below:
Connect the aluminum wiring using special connectors and/or
tools designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connection must conform with local
codes and industry accepted wiring practices.
INSTALLATION INSTRUCTIONS
Prepare Location
1. Decide on the final location for the cooktop.
NOTE: Countertop must be 1
3
16
" (3.0 cm) to 2" (5.1 cm) thick.
2. If necessary, make cutout in countertop before installing
cooktop. See “Location Requirements” section for more
information.
3. Clean cutout of any remaining dust and debris.
X
Y
A
Detail A
A
B
A. R14.7 ± 0.5 - For Whirlpool and Maytag,
R8 ± 0.5 - For KitchenAid
B. R5.5 ± 0.5
Glass Radius (Whirlpool and Maytag) - 12.7 mm
Glass Radius (KitchenAid) - 6mm
Electrical Requirements
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Check with a qualified electrical installer if you are not sure the
cooktop is properly grounded.
It is not recommended to have a fuse in the neutral or ground
circuit.
Model X Y
30" 31" (78.7 cm) 21
7
/
16
" (54.5 cm)
36" 36
1
/
2
" (92.7 cm) 21
7
/
16
" (54.5 cm)