11
Complete Installation
Electronic Ignition System
Initial lighting and gas flame adjustments
Surface burners use electronic igniters in place of standing pilots.
When the cooktop control knob is turned to the “IGNITE” position,
the system creates a spark to light the burner. This sparking
continues, as long as the control knob is turned to “IGNITE”.
Check Operation of Surface Burners
Push in and turn the surface burners control knobs to light.
The surface burner flame should light within 4 seconds. The first
time a surface burner is lit, it may take longer that 4 seconds to
light because of air in the gas line.
Check the flame on “HIGH” for a blue color. It should be clean and
soft in character. No yellow tip, blowing or lifting of flame should
occur. Occasional orange flashes are normal and reflect different
elements in the air or gas.
After verifying the proper burner operation, turn the control knobs
to “OFF.”
If burners do not light properly:
Turn surface burner control knob to the “OFF” position.
Check that the power supply cord is plugged in and the circuit
breaker has not tripped or the fuse blown.
Check that the gas shutoff valve is set to the “open” position.
Check that burner caps are properly positioned on burner
bases.
A
B
A. Incorrect
B. Correct
Recheck operation of surface burners. If a burner does not light at
this point, contact your dealer or authorized service company for
assistance.
Check Flame Height
Adjust the height of surface burner flames.
The surface burner low flame should be a steady blue flame
approximately 1/4" (6.4 mm) high.
A. Low flame
B. High flame
Adjustment for Single Valve:
1. Set the burner flame to LO.
2. Remove the control knob.
3. Hold knob stem with a pair of pliers. Use a 3/32" (#0 [2 mm])
flat-blade screwdriver to turn the screw located within the shaft
of the control knob stem until the flame is the proper size.
Turn adjustment screw “C” to the right to reduce flame height,
turn adjustment screw to the left to increase flame height.
A. 3/32" (#0 [2.0 mm]) flat-blade screwdriver
(screwdriver shaft must be a minimum of 2" [5.1 cm]
long)
B. Control knob stem opening
C. Adjustment screw location
4. Replace the control knob.
5. Test the flame by turning the control from LO to HI, checking
the flame at each setting.
IMPORTANT: Dual valve adjustments must be performed by a
qualified installer or service agency.
Power failure
In case of prolonged power failure, the surface burners can be lit
manually. Hold a lit match near a burner and turn knob
counterclockwise to IGNITE/Lite/
. After burner lights, turn knob
to setting. Do not use a grill or griddle accessory during a power
failure as the vent fan will not operate.
GAS CONVERSIONS
IMPORTANT: Gas conversions from Natural gas to Propane gas
must be done by a qualified installer. Before proceeding with
conversion, shut off the gas supply to the appliance prior to
disconnecting the electrical power.
WARNING:
This conversion kit shall be installed by a qualified
service agency in accordance with the manufacturers
instructions and all applicable codes and requirements of
the authority having jurisdiction. If the information in
these instructions is not followed exactly, a fire, an
explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life.
The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and
complete until the operation of the converted appliance is
checked as specified in the manufacturers instructions
supplied with the kit.