BURNER AND NOZZLE SPECIFICATIONS
CATEGORY
II2H3+
Type of gas used Type of burner Injector
marking
Rated thermal
ow rate
kW
Rated
consumption
Reduced heat
capacity
kW
Gas pressure
mbar
min. rat. max.
NATURAL GAS
(Methane) G20
Rapid
Semi-rapid
Auxiliary
115 Y
95 Z
72 X
3,00
1,65
1,00
286 l/h
157 l/h
95 l/h
0,70
0,40
0,40
17 20 25
LIQUEFIED
PETROLEUM GAS
(Butane) G30
Rapid
Semi-rapid
Auxiliary
85
63
50
3,00
1,65
1,00
218 g/h
120 g/h
73 g/h
0,70
0,40
0,40
20 28-30 35
LIQUEFIED
PETROLEUM GAS
(Propane) G31
Rapid
Semi-rapid
Auxiliary
85
63
50
3,00
1,65
1,00
214 g/h
118 g/h
71 g/h
0,70
0,40
0,40
25 37 45
Type of gas used Model conguration
4BURNERS
Rated thermal owrate
(kW)
Total rated consumption Air required (m
3
) for burning
1m
3
of gas
G20 20 mbar 1R - 2SR - 1AUX 7,30 695 l/h 9,52
G30 28-30 mbar 1R - 2SR - 1AUX 7,30 531 g/h 30,94
G31 37 mbar 1R - 2SR - 1AUX 7,30 521 g/h 23,80
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz - 0,6 W

Bekijk gratis de handleiding van Whirlpool TKRL 650 IX, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkWhirlpool
ModelTKRL 650 IX
CategorieFornuis
TaalNederlands
Grootte8379 MB

Caratteristiche Prodotto

ApparaatplaatsingIngebouwd
Soort bedieningDraaiknop
Kleur van het productRoestvrijstaal
Ingebouwd displayNee
Gewicht7000 g