Troubleshooting
When the system is
turned on or working, the
wired controller displays
code "E8" and the buzzer
alarms the fault.
1. Check if the exhaust passage is blocked.
2. Stop starting, and start after no strong
wind in the outdoor.
3. Remove the heat exchanger, use a
brush to gently clean the carbon on the
fins,and ensure that the type and
pressure of the gas used subsequently
meet the requirements of the water
heater.
2. The outdoor wind pressure is too high,
and the fan speed exceeds the upper
limit of the speed.
3. A large amount of carbon in the heat
exchange fins (when the gas source is
used incorrectly), causing blocked, and
the fan speed increase exceeds the
upper limit of the speed.
1. During operation, the fan speed
continuously exceeds the set value of
5S speed.
During the system
working process, the
wired controller displays
"En" and the buzzer
alarms the fault.
1. Set the appropriate time according to
the usage habits, and the timed
shutdown time can be set to 20, 30, 40,
50, 60 minutes.
2. It is not necessary to set "OFF" to turn
off the timing function.
In order to prevent oxygen deficiency,
some models have timing protection.
Please turn off the tap and use it after a
while.
Fault alarm release and reset method: If the above code appears, please check the waterway, the gas path is
normal, press "Switch button" to turn off or turn off the power to restart. The water heater is restored to normal
use. lf the above operations cannot be resumed, please notify the after-sales service personnel.
Error Code
Fault Handling
Possible Cause