Westinghouse HW120A16 handleiding

80 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 23 van 80
Installation
3.13 Gas Connection
Ÿ During any system stress test where the test
pressure exceeds 1/2 psi (3.5 KPa), it must be the
water heater and its separate shut-off valve are
disconnected from the air supply piping system.
3. Always remove any debris and/or water gas lines
before connecting to the air intake.
1. Install a manual gas shut-off valve between the
water heater and the air supply line.
Ÿ During pressure testing of any gas supply piping
system with a test pressure equal to or less than
1/2 psi (3.5 KPa), the water heater must be
isolated from the air supply piping system by
closing its separate manual shut-off valve.
2. When the gas connection is completed, the gas
leak test must be performed by applying soapy
water to all gas fittings and observing the air
bubbles or using a gas leak detection device.
WARNING
3. Turn off the gas.
1. A licensed professional must install the
gas supply.
5. Do not turn on the water heater or gas
until all fumes are gone.
2. Turn off 120v power supply.
4. Gas is flammable. Do not smoke or
provide other ignition sources while
working with gas.
NOTICE
Do not use this product if any parts are
underwater. Contact the installer or service
agency immediately to replace the flooded
water heater. Do not try to repair the heater.
Replacement must be done!
gas water heater
Teflon tape
hose joint
buckle
rubber pipe
NOTICE
Use sealant tape or other approved sealing
method on the threads for a secure, no
water or gas leakage.
water outlet
gas inlet
water inlet
water outlet pipe
gas pipe
water inlet pipe
3.14 Water Connection
WARNING
Do not use this product if any parts are
underwater. Contact the installer or service
agency immediately to replace the flooded
water heater. Do not try to repair the
heater. Replacement must be done!
NOTICE
Do not reverse the hot and cold inlet
connections of the water heater. if
connected in reverse, the water heater will
not start properly.