Installation
3.7 Venting Instructions
WARNING
Ÿ Improper installation can result in nausea
or suffocation, serious injury or death
from carbon monoxide and smoke
poisoning. Improper installation will void
the product warranty.
Ÿ Improper installation of ventilation on this
equipment can result in excessive carbon
levels and carbon monoxide can cause
severe personal injury or death.
Ÿ Place the water heater as close as possible to the
vent termination.
Indoor models must be vented according to the
current version of the National Gas Code "Equipment
Exhaust" section: US ANSI z 223.1/NFPA 54 and/or B
149.1 natural gas section 8 Canadian propane and
propane installation specifications, And applicable
local building codes.
General rules for venting water heaters:
Ÿ Exhaust pipe must be easily removed from the top
of the water heater for proper service and
inspection.
Ÿ Avoid using oversized exhaust pipes or using
extremely long pipes unless it is part of an
approved general exhaust system.
Ÿ For roof ventilation, a rain cap or other form of
terminal must be installed to prevent rain from
entering indoor.
Ÿ Provisions for adequate combustion and ventilation
air in accordance with one of the following:
A) The National Fuel Gas Code, ANSI Z223.1/NFPA
54.
C) Applicable provisions of the local building code.
B) CSA B149.1, Natural Gas and Propane Installation
Code.
Ÿ Minimum clearances from combustible or
noncombustible construction,6 inches sides,0
inches back, and 12 inches top. Minimum clearance
from Type B flue or vent connector to combustible
construction 1 inches. Type B Vent or Vent
connector shall be used.
Ÿ A water heater shall not be connected to a chimney
flue serving a separate appliance, designed to burn
solid fuel.
Ÿ When the appliance is installed directly on
carpeting, the appliance shall be installed on a
metal or wood panel extending beyond the full
width and depth of the appliance by at least 3 in
(76.2 mm) in any direction or, if the appliance is
installed in an alcove or closet, the entire floor shall
be covered by the panel. The panel must be strong
enough to carry the weight of the heater when
running.
CAUTION
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
Ÿ Avoid placing the water heater exhaust terminal
near any indoor air intake. These fans can take the
exhaust flue products out of the water heater and
return them to the building. This can be harmful to
your health.
Ÿ General rules for the termination of vents:
Ÿ Locate the exhaust terminal so that it will not be
blocked by any debris at all times. Most
specifications require the terminal to be at least 12
inches (305 mm) above grade and the expected
snow level, but the installer can determine if it
should be higher based on job site conditions and
applicable specifications.
Ÿ The water heater should not be connected to the
chimney flue of a separate unit used to burn solid
fuel.