3.4 Determine Installation Location
You must ensure that clearances will be met and that
the vent length will be within required limits. Consider
the installation environment, water quality, and need
for freeze protection. Requirements for the gas line,
water lines, electrical connection, and condensate
disposal can be found in their respective installation
sections of this manual.
Water quality
The water must be potable, free of corrosive
chemicals, sand, dirt, or other contaminates. It is up
to the installer to ensure the water does not contain
corrosive chemicals, or elements that can affect or
damage the heat exchanger. Water that contains
chemicals exceeding the levels below affect and
damage the heat exchanger. Replacement of the heat
exchanger due to water quality damage is not
covered by the warranty.
Consideration of care for your water heater should
include evaluation of water quality.
Environment
Air surrounding the water heater, venting, and vent
termination(s) is used for combustion and must be
free of any compounds that cause corrosion of
internal components. These include corrosive
compounds that are found in aerosol sprays,
detergents, bleaches, cleaning solvents, oil based
paints/ varnishes, and refrigerants. The air in beauty
shops, dry cleaning stores, photo processing labs,
and storage areas for pool supplies often contains
these compounds.
The water heater, venting, and vent termination(s)
should not be installed in any areas where the air may
contain these corrosive compounds. If it is necessary
for a water heater to be located in areas which may
contain corrosive compounds, the following
instructions are strongly recommended.
Therefore it is recommended that outdoor models be
used for these locations where possible.
WARNING
Ÿ Before installation, consider where air has
the ability to travel within the building to
the water heater.
Ÿ Make sure the equipment has adequate
combustion air and proper ventilation.
Failure to do so may result in carbon
monoxide poisoning or death.
Ÿ Chemicals that are corrosive in nature
should not be stored or used near the
water heater.
Ÿ DO NOT Install in areas where air for
combustion can be contaminated with
chemicals.
WARNING
Ÿ Chemicals that are corrosive in nature
should not be stored or used near the
water heater or vent termination.
Ÿ Install the water heater as far away as
possible from exhaust vent hoods.
Ÿ Install as far away as possible from air
inlet vents. Corrosive fumes may be
released through these vents when air is
not being brought in through them.
Installation
Ÿ Chemicals that are corrosive in nature should not
be stored or used near the water heater.
Ÿ Before installation, consider where air has the
ability to travel within the building to the water
heater.
Ÿ DO NOT Install in areas where air for combustion
might be contaminated with chemicals.
Ÿ Where possible, install the water heater in a sealed
closet so that it is protected from the potential of
contaminated indoor air.