4.6 Voltage Selector and Fuses
4.6.1 Voltage Selector
The Supercarrier II can be configured to operate at either 230V or 115V. Please note that your unit is pre-
configured for the specific sales region, including the appropriate fuse setup for either 230V or 115V. If you
need to change the voltage configuration using the power selector, make sure to also use the correct fuse
for the new voltage setting.
For proper operation, you can change the voltage and ensure the correct fuse is installed based on
your voltage setting. Use:
2A fuse for 115V
1A fuse for 230V
Important: Incorrectly setting the voltage selector can cause severe damage to the unit and result in the
fuse blowing. For example, if the voltage selector is set to 115V while connected to a 230V supply, the unit
may experience overloading, leading to a blown fuse and potential harm to the device.