1) INPUT – Adjusts the input signal level, with a range from -15dB to +15dB.
2) THRESHOLD – Sets the threshold level where the compressor begins to act. The threshold is fully
adjustable.
3) OUTPUT – Adjusts the output signal level, with a range from -15dB to +15dB.
4) ATTACK – Controls the speed of the compressor's response to incoming signals, with six selectable
attack times: 0.5, 1, 3, 10, 20, and 50 milliseconds.
5) MIX - Mixes wet and dry signals for parallel compression.
6) RELEASE – The release time can be switched between 0.1, 0.3, 0.6.
7) THD – Controls the harmonic distortion applied to the wet signal, with two selectable modes: MED (1%
THD) and HIGH (2.5% THD).
8) A/B – Two memory slots that allow you to compare different compressor settings.
9) SC FILTER - This button selects between three side-chain high-pass filter frequencies (60Hz, 90Hz,
150Hz).
10) BYPASS – Bypass Switch.
11) USB socket – Module control USB port.
12) DATA LED – Indicates that data is being transmitted from the DAW to the device.
13) H-LINK LED – Shows the status of the connection between the host and the module.
14) GR METER – Analogue GR meter indicating current gain reduction.