WESAUDIO
8/13/24
_RHEA USER MANUAL V2
13
1) INPUTAdjusts the input signal level, with a range from -15dB to +15dB.
2) THRESHOLD Sets the threshold level where the compressor begins to act. The threshold is fully
adjustable.
3) OUTPUT Adjusts the output signal level, with a range from -15dB to +15dB.
4) ATTACK Controls the speed of the compressor's response to incoming signals, with six selectable
attack times: 0.5, 1, 3, 10, 20, and 50 milliseconds.
5) MIX - Mixes wet and dry signals for parallel compression.
6) RELEASEThe release time can be switched between 0.1, 0.3, 0.6.
7) THD Controls the harmonic distortion applied to the wet signal, with two selectable modes: MED (1%
THD) and HIGH (2.5% THD).
8) A/BTwo memory slots that allow you to compare different compressor settings.
9) SC FILTER - This button selects between three side-chain high-pass filter frequencies (60Hz, 90Hz,
150Hz).
10) BYPASS – Bypass Switch.
11) USB socket – Module control USB port.
12) DATA LEDIndicates that data is being transmitted from the DAW to the device.
13) H-LINK LEDShows the status of the connection between the host and the module.
14) GR METER – Analogue GR meter indicating current gain reduction.