Wells MOD427 handleiding

40 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 28 van 40
M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
WIRING DIAGRAM: Innite Control Units
26
L
2
L
3
1
L
5
TERM. BLOCK
SINGLE PHASE
240
10.0
86
7
1
3
2
4
8.7
208
REV. I PN 2M-31222
WIRING DIAGRAM FOR MODULAR 200 WARMER
P L L
1
2
2
H
H
1
INFINITE
SWITCH (2)
PILOT
LIGHT (2)
2
1
LLP
2
1
H
H
AMPS
VOLTS
208/240V SINGLE PHASE
SER. NO. WM 1000 & UP
SAFETY
THERMO (2)
ELEMENT
(2)
DVP
H
SEE ECN-12847
DTL 05-12-05
.000 =.005
-
+
.00 =.020
-
+
.0 =.030
+
-
35758
DTL
MOD-300
DIAGRAM WIRING
.1-16-95
BWC
ENG. REL. ECN-8553
G
WELLS
BY APP
UNLESS NOTED
-
+
ANG.
DEC.
TOL.
PART NO.
VERDI, NV.
PART NAME
USED ON
SCALE DWN. ENG.
CKD.
DO NOT SCALE DWG.
MATERIAL
REVISIONS
ISSUE
WAS
DATE
1
O
*
NONE
W/#467 PERMANENT ADHESIVE BACK
H
35758
ISSUE
SH. OF
1 1
BLOOMFIELD
D.C
. G.C
3 X 5 LABEL ON WHT STOCK
L.M
Z
H
60
50
SINGLE PHASE
15.0
13.0
8.7
7.5
8.7
7.5
4
2
1
3
1
1614
1513
12
11
TERM. BLOCK
THREE PHASE
240
8.7
7.5
208
REV. H PN 2M-35758
WIRING DIAGRAM FOR MODULAR 300 WARMER
1
L
1
3
L
2
L
L
2
1
L
NOM. AMPS PER LINE
THREE PHASE
L3L2
VOLTS
6
5
ELEMENT
(3)
2
H
2
P L L
1
2
H
1
P L L
1
2
2
H
H
1
INFINITE
SWITCH (3)
PILOT
LIGHT (3)
3
5
4
2
1
LLP
2
1
H
H
6
L1
SINGLE
PHASE
208/240V SINGLE PHASE OR THREE PHASE
SER. NO. MOD-300 MW 1000 & UP
SAFETY
THERMO (3)
MOD200 & MOD227 Series
MOD300E & MOD327E Series